10 Mil Dura Skrim® Fire Retardant Reinforced Plastic Sheeting
Heavy-duty, fire-retardant reinforced poly sheeting built for containment, abatement, and jobsite protection where flame spread is a real concern.
10 Mil Dura Skrim® Fire Retardant Reinforced Plastic Sheeting (DS10FR) is a three-layer, string-reinforced polyethylene film engineered for construction enclosures, asbestos abatement, fumigation covers, and temporary walls. The fire-retardant formulation meets NFPA 701 Test Method 2 (Large Scale) and carries a Class A flame spread rating under ASTM E84, making it the go-to choice for contractors who need a tear-resistant, code-compliant containment film in a single product.
💡 Built for fire-rated containment. When your scope of work requires NFPA 701-compliant sheeting with the tear strength to survive real jobsite conditions, DS10FR delivers both — without forcing you to choose between fire performance and durability.
Features and Benefits of 10 Mil Dura Skrim® Fire Retardant Sheeting
Three-Ply Reinforced Construction
DS10FR consists of two sheets of high-strength fire-retardant virgin polyethylene film laminated together with a third layer of molten polyethylene. A heavy-duty scrim reinforcement is sandwiched between the plies, dramatically increasing tear resistance and extending service life on demanding jobsites. The result is a 10 mil reinforced poly that holds up under wind load, foot traffic near openings, and repeated handling during phased work.
NFPA 701 and ASTM E84 Fire Performance
The fire-retardant film meets or exceeds NFPA 701 Test Method 2 (Large Scale) and qualifies as a Class A Wall and Ceiling Finish under NFPA Life Safety Code 101 (tested per ASTM E84-97a). Flame Spread Index is 5 and Smoke Developed Value is 55 — well within Class A thresholds. As a result, DS10FR can be specified in occupied buildings, hospitals, schools, and other environments where authorities having jurisdiction require documented fire performance for temporary enclosures.
High Puncture and Tear Strength
The internal scrim grid resists tear propagation, so a small puncture stays a small puncture instead of running the length of the panel. Trapezoid tear strength of 44 lbf and grab tensile of 75 lbf give the material the toughness contractors need for negative-pressure containments, temporary curtain walls, and ceiling protection in active work zones.
Moisture Barrier Performance
With a WVTR of 0.214 grains/(100in²·day) and a perm rating of 0.031 (ASTM E96 Procedure B), DS10FR also functions as an effective vapor and moisture barrier. That dual function matters on abatement and restoration jobs where you’re controlling both contaminants and humidity at the same time.
Accordion-Folded Panels for Faster Install
All panels — stock or custom — are accordion folded and tightly rolled on a heavy-duty core. Crews unfold the panel directly into position, which cuts hanging time on tall walls and overhead containments. Custom prefabricated panels are available up to 100,000 square feet, which means fewer seams to tape and fewer failure points on large enclosures.
🌱 Ideal for: abatement and remediation contractors, general contractors building temporary enclosures, fumigation professionals, and restoration crews working in occupied buildings.
Why Fire-Retardant Reinforced Sheeting Matters on the Jobsite
Standard polyethylene sheeting burns. On most jobsites that’s not a code issue — but the moment you’re inside an occupied building, near hot work, or operating under a fire marshal’s review, untreated poly is a liability. Specifying a fire-retardant reinforced film up front avoids stop-work orders, failed inspections, and the cost of tearing down and replacing non-compliant containment mid-project.
Reinforcement matters for a different reason. Non-reinforced 10 mil film tears easily once punctured, which means a single nick can compromise an entire wall of containment. String-reinforced construction stops tears from running, so the enclosure stays intact through the duration of the work.
| Feature | Benefit |
|---|---|
| NFPA 701 + ASTM E84 Class A | Passes fire marshal review in occupied buildings, hospitals, and schools. |
| String-Reinforced Scrim | Tears stop spreading, so one puncture doesn’t compromise the entire panel. |
| 10 Mil Three-Ply Construction | Stands up to wind load, foot traffic, and repeated handling on long jobs. |
| 0.031 Perm Rating | Doubles as a vapor barrier on remediation and restoration work. |
| Custom Panels to 100,000 sq ft | Fewer seams on large enclosures means less tape, less labor, fewer leaks. |
| Accordion-Folded Rolls | Crews unfold panels into position, cutting hanging time on tall walls. |
💰 One product, two problems solved. Buying a fire-retardant reinforced film instead of stocking separate FR poly and reinforced poly consolidates SKUs and eliminates the risk of grabbing the wrong roll on the wrong job.
Common Applications for 10 Mil DS10FR Sheeting
DS10FR is specified across construction, environmental, and industrial trades wherever fire-retardant containment is required:
- Construction enclosures — temporary weather and dust barriers on active sites
- Asbestos abatement — negative-pressure containment for Class I and Class II work
- Fumigation covers — tarping structures during pest control treatment
- Temporary walls — partitioning occupied buildings during renovation
- Containment curtains — separating clean and work zones on healthcare and data center projects
- Jobsite coverings — protecting finished work, equipment, and materials
- Lead and mold remediation — sealed enclosures for hazardous material removal
- Hot work protection — barriers near welding, cutting, and grinding operations
🌑 Need a lighter or heavier option? For thinner fire-retardant containment, see our full lineup on the fire retardant plastic sheeting resource page. Our team can help you match mil thickness to the scope of work.
Technical Specifications
| Property | Test Method | Value |
|---|---|---|
| Appearance | — | Translucent, White |
| Thickness (Nominal) | — | 10 mil (0.25 mm) |
| Weight | — | 40.5 lbs/MSF (198 g/m²) |
| 1″ Tensile Strength | ASTM D7003 | 57 lbf/in (100 N/cm) |
| Elongation at Film Break | ASTM D7003 | 500% |
| Grab Tensile | ASTM D7004 | 75 lbf (334 N) |
| Trapezoid Tear | ASTM D4533 | 44 lbf (196 N) |
| Mullen Burst | ASTM D751 | 75 psi (517 kPa) |
| Max Static Use Temperature | — | 180°F (82°C) |
| Min Static Use Temperature | — | -70°F (-57°C) |
| WVTR | ASTM E96 Procedure B | 0.214 grains/(100in²·day) |
| Perm Rating | ASTM E96 Procedure B | 0.031 Perms |
| Flame Spread Index | ASTM E84 Procedure A | 5 |
| Smoke Developed Value | ASTM E84 Procedure A | 55 |
Stock sizes:
- 6.75′ x 100′
- 20′ x 100′
Custom fabrication: Prefabricated panels available up to 100,000 sq ft. Contact your account manager for sizing, pricing, and lead times.
Frequently Asked Questions
Does 10 Mil Dura Skrim® FR meet NFPA 701 fire code requirements?
Yes. DS10FR meets or exceeds NFPA 701 Test Method 2 (Large Scale Requirements) and also qualifies as a Class A Wall and Ceiling Finish under NFPA Life Safety Code 101, tested per ASTM E84-97a. The Flame Spread Index is 5 and the Smoke Developed Value is 55.
What is the difference between fire-retardant and fire-resistant plastic sheeting?
Fire-retardant films are formulated to resist ignition and self-extinguish, slowing flame spread — they will still degrade in sustained fire. Fire-resistant typically refers to materials with much higher temperature ratings, such as welding blankets or rated wall assemblies. For temporary containment and enclosures, fire-retardant sheeting like DS10FR is the standard specification.
Can 10 Mil Dura Skrim® FR be used for asbestos abatement?
Yes. DS10FR is widely used for negative-pressure containment in asbestos, lead, and mold abatement projects. The string reinforcement resists tears that could compromise containment integrity, and the fire-retardant rating allows use in occupied buildings where fire marshals require it.
💡 Pro tip: Order prefabricated panels sized to your enclosure dimensions instead of seaming standard rolls in the field. Fewer seams means faster install, less tape, and fewer potential leak points on negative-pressure containments.
What sizes are available for DS10FR sheeting?
Americover stocks DS10FR in 6.75′ x 100′ and 20′ x 100′ rolls. Custom prefabricated panels are available up to 100,000 square feet, accordion folded on a heavy-duty core for installation.
Is 10 Mil Dura Skrim® FR a vapor barrier?
Yes. With a perm rating of 0.031 and a WVTR of 0.214 grains/(100in²·day) per ASTM E96 Procedure B, DS10FR functions as a Class I vapor retarder in addition to its containment role. That makes it useful on remediation jobs where both contaminants and moisture need to be controlled.
How is DS10FR installed?
Panels are typically attached to wall framing, ceiling grid, or temporary stud walls using poly-hangers, staples, tape, or spray adhesive depending on the substrate. Accordion folding lets crews unfold the sheet directly into position, which speeds up installation on tall walls and overhead containments. Seams are sealed with compatible containment tape.
What is the shelf life of Dura Skrim® FR sheeting?
When stored indoors, out of direct sunlight, and in original packaging, DS10FR has a long shelf life. Outdoor service life depends on UV exposure, weather, fastening method, and jobsite conditions — fire-retardant polyethylene films are not designed for long-term exterior installation.
Contractors working in occupied buildings consistently come back to DS10FR for one reason: it passes inspection and survives the job. For project pricing, custom panel quotes, or help matching mil thickness to your scope, contact Americover at 800-747-6095 or sales@americover.com.